The Elektror industrial fans are used for transporting air or gases. All models are designed for permanent operation. The supplied portfolio includes low-pressure, medium-pressure and high-pressure industrial fans. The fans are made not only in a standard design, but also using special stainless steel or in a gas-sealed design. Moreover, versions for explosive environments (ATEX) are also available.

Industrial fans by power output:

    Low-pressure fans up to 2,200 Pa

 

 

 

 

 

 

Low-pressure fans up to 2,200 Pa

Low-pressure fans are suitable for operation at a pressure of up to 2,200 Pa. The fan is mounted directly on the shaft of the electric motor. The stator is made of aluminium and the impeller of zinc-covered sheet metal. They are also available in a stainless steel version and a version for explosive environments (ATEX)

Key parameters of low-pressure fans:

  • Pumping speed: from 3.2 m3/min to 95 m3/min
  • Motor power: from 0.03 kW to 4 kW
  • Max. vacuum: 0 – 1,900 Pa
  • Max. overpressure: 0 – 1,900 Pa

Applications and usage examples of low-pressure fans:

  • Sources for discharging vapors and for blowing.
  • Low-pressure fans are used as sources of both pressure and negative pressure for pipe mail.
  • They can be part of ventilation systems where they serve as air sources.

    List of low-pressure fan models can be found here ►
 

 

    Středotlaké ventilátory

 

 

 

 

 

 

 

Medium-pressure fans up to 10,500 Pa

Medium-pressure fans are suitable for operation at pressure differences of 9,600 Pa. The fans have a direct drive and can include an integrated frequency converter (FUK) The stator and the impellers are normally made of aluminum. They are also available in a stainless steel version and a version for explosive environments (ATEX)

Key parameters of medium-pressure fans:

  • Pumping speed: from 2.7 m3/min to 125 m3/min
  • Motor power: from 0.04 kW to 22 kW
  • Max. vacuum: 0 – 9,600 Pa
  • Max. overpressure: 0 – 9,600 Pa
Applications and usage examples of medium-pressure fans:
  • Thanks to their characteristics, medium-pressure fans can handle hot air up to 230 °C. They are therefore used for ventilation or drying.
  • With the ATEX modification, they can be used in more demanding environments such as biogas plants, landfills or wastewater treatment plants.
  • They are also used in incineration plants, where they supply compressed air to the incinerator furnaces.
  • They form a part of the equipment for cooling, degassing, dehumidification or drying.

    List of medium-pressure fan models can be found here ►
 

 

    High-pressure fans up to 17,300 Pa

 

 

 


 

 

High-pressure fans up to 17,300 Pa

High-pressure fans are suitable for operation at pressure differences of 17,300 Pa. The fan is mounted directly on the shaft of the electric motor. The fan may include a frequency converter (FUK) mounted on the motor. Other versions can have a belt drive and can be operated up to high speeds of up to 6,200 rpm. They are also available in a stainless steel version and a version for explosive environments (ATEX).

Key parameters of high-pressure fans:

  • Pumping speed: from 5.5 m3/min to 96 m3/min
  • Motor power: from 0.03 kW to 18.5 kW
  • Max. vacuum: 0 – 17,300 Pa
  • Max. overpressure: 0 – 17,300 Pa

Applications and usage examples of high-pressure fans:

  • High-pressure fans form an integral part of ventilation systems where they serve as sources of the circulating air.
  • It is also an ideal means for aerating and ventilating various areas and workplaces, such as painting facilities or welding workplaces.
  • With the ATEX modification, they can also be used in chemical factories or biogas plants.
  • They are not affected by slightly volatile pollutants, and they can ventilate air from the galvanizing baths.

    List of high-pressure fan models can be found here ►
 

 

   

 

velkoobjemé průmyslové ventilátory

 

 

 

 

 

 

 

 

High-volume Elektror fans from 25,000 to 400,000 m3/h

This type of the Elektror fans forms a standardized series of the fans. Every fan is tailored to the corresponding application. The fans can be made with a direct connection, clutch connection or belt connection. The fan speed is usually controlled by a frequency converter. The impellers are made of steel or stainless steel. It is also possible to prepare versions for explosive environments (ATEX). The orientation of the exhaust and the rotation direction are adjustable.

Key parameters of large-volume fans:

  • Pumping speed: up to 400,000 m3/min
  • Motor power: from 0.03 kW to 4 kW
  • Max. vacuum: 0 – 35,000 Pa
  • Max. overpressure: 0.75 – 500 Pa

Applications and usage examples of large volume fans:

  • They are used for extraction and ventilation of odors in livestock production.
  • It is used for extraction of procedural air from heat exchangers in incineration and heating plants.
  • They provide procedural air for the production of technical and explosive gases (ATEX modified).
  • In the woodworking industry, they are used for sawdust extraction from woodworking machines.

    List of large-volume fan models can be found here ► ►
 

Industrial fans by their usage manner:

   

 

Fans for explosive environments

 

Ventilátory do výbušného prostředí série HRD FU/FUK

 

 

 

 

 

 

 

 

Fans for explosive environments

Fans for explosive environments, Elektror ND ATEX, Elektror RD ATEX and Elektror HRD FU/FUK series are made of an aluminum alloy. All series are designed for the transport of air and explosive gases. The rotor is made of galvanized steel sheet. Dynamically balanced impellers guarantee low noise and high efficiency. Their design is ready for installation in both three-phase and single-phase motors. The motors have a spark protection. ATEX is supplied with the fan as a unit.

The Elektror ND ATEX low-pressure fans have a power output of up to 95 m³/min and 2,200 Pa.

The Elektror RD ATEX medium-pressure fans have a power output of up to 142 m³/min and 10,600 Pa.

The Elektror HRD FU/FUK high-pressure fans have a power output of up to 100 m³/min and 17,300 Pa. With a higher speed up to 105 Hz (approx. 6,200 rpm). These series have a direct drive via a remote frequency converter (FU) or built-in frequency converter (FUK).  .

Key parameters of the Elektror fans include:

  • transport of air and explosive gases
  • grading of logical power outputs
  • low noise level
 
  • robust cast aluminum housing
  • variable speed control
  • ATEX design

Applications and usage examples of the fans for explosive environments:

  • They are used for extraction of explosive gases and vapors.
  • It is used for cooling and ventilation of machining components.
  • They can be used as an air source for room ventilation.
  • They are used as an air source for transport systems.
  • They are the solution for improving chimney traction.
  • They can be used for outdoor ventilation of electrical machines.
  • They serve as an air source for gas, oil and coal systems.
  • They can be applied as an air source for dryers and drying rooms.
  • They are also used for air extraction during welding.

    List of the fan models for explosive environments can be found here ►
 

 

   

Vanoběžné radiální ventilátory PFL

Vanoběžné radiální ventilátory PFL

Idle radial fans

Idle radial industrial fans achieve a pumping speed of up to 300,000 m³/h (5,000 m³/min) and a maximum overpressure of up to 3,300 Pa. Idle fans can be supplied with a direct drive, clutch box drive, belt drive or frequency inverter control.

The fans are standardized, but also tailored to each application.

Key benefits and functions of idle fans include:

  • pumped gas temperature up to 250 °C
  • motor housing with forced ventilation
  • extremely robust and compact design
  • suitable for installations in aeration chambers

Applications and usage examples:

 

 

   

Axial fans

Axial fans

 

Axial fans

MAF industrial axial fans can deliver up to 200,000 m³/h (3,300 m³/min) and 2,000 Pa. MAFC series 145,000 m³/h (2,500 m³/min) and 5,200 Pa. Both series can be supplied with either a direct drive, belt drive or frequency converter.

Fans in this production range are designed specifically to meet the requirements of a particular project.

Key benefits and functions include:
  • rotary axial fan
  • increased protection class
  • suitable for extremely high pressures
  • strong sound insulation
 
  • for temperatures of up to 750°C
  • thermal insulation
  • UL, EAC and CSA certifications
  • ATEX design
Applications and usage examples:
  • They provide fresh air supply during operation.
  • They are used in power plant operations.
  • They provide air extraction from production lines.
  • They serve as air sources for the air pylons during the Red Bull Air Races

    List of Elektror axial fans can be found here ►
 

 

   

Conveyor fans

Conveyor fans

Conveyor fans

Conveyor fans are primarily designed for a direct transport of light bulk materials. Materials should not be abrasive or explosive. Conveyor fans are used for vacuum and overpressure transport of materials. The valves can be supplied with a direct phonon, clutch drive or frequency converter control. Aluminum alloy covers, open transport impellers made of steel. That ensures corrosion resistance.

Elektror RDF conveyor fans have a capacity of up to 64 m³/min and a pressure differential of up to 7,150 Pa.

Elektror CFMT conveyor fans have a capacity of up to 12,000 m³/h (200 m³/min) and a pressure differential of up to 4,250 Pa. Fans can be supplied with an electric motor or an internal combustion motor.

Key benefits and functions include:
  • low noise level
  • robust construction
  • low operating cost
  • long service life
 
  • power regulation
  • for higher temperatures
  • UL, EAC and CSA certifications
  • ATEX design

Applications and usage examples:

  • Conveyor fans are designed for transporting light bulk materials.
  • CFMT series fans are used as fresh air sources. They also provide procedural air for the production of technical gases and insulation materials. They can also be used for fume extraction in paint shops, incineration plants and other processes.

    List of Elektror conveyor fans can be found here ►
 

 

   

Střešní ventilátory MAFR

 

 

 

 

 

 

 

 

 

Roof fans

The Elektror MAFR roof fans have a capacity of up to 67,000 m³/h (1,100 m³/min) and 1,100 Pa. They are supplied either with a direct belt drive operation or with a frequency converter. The fans are made of stainless steel. The impellers are made of plastic or aluminum. The fan blades create an air vacuum during movement, which comes out of the fan already under pressure. The fan is weatherproof. They are always sized individually pursuant to the given project.

Available in a two-stage design or with a frequency converter.

Key benefits and functions include:
  • made of galvanized steel
  • rotation speed control
  • resistance to gases and vapors
 
  • aluminum (plastic) rotor
  • almost maintenance-free motors
  • direct drive from motor holder B3

Applications and usage examples:

  • The fans form a part of ventilation systems in residential and non-residential areas.
  • They are applied in ventilation systems of industrial production plants.
  • They are also used in ventilation systems of agricultural facilities.
  • They can be used on flat, arched, single- and double-leaf roofs.

    List of Elektror roof fans can be found here ►
 

Service of industrial fans:

  • Sale of industrial fans and vacuum technologies
  • Warranty and post-warranty service of Elektror industrial fans
  • Fan service at the customer's site
  • Repairs and refurbishing of industrial fans
  • Official Elektror service for the Czech Republic and Slovakia

VAKUUM BOHEMIA, s.r.o. services:

  • Design and delivery of customized vacuum and pressure systems
  • Training in the field of vacuum solutions
  • Consultingin the field of vacuum technologies
  • Design of fan systems
  • Repairs and refurbishing of the Elektror fans

Industrial fans are used in the following industrial fields:

  • They are also used in heating plants and incineration plants, where they form a part of evaporators. They supply compressed air to the incineration furnaces.  Hot air industrial fans, ATEX fans as well as other fan types are available.
  • Industrial fans form a part of the equipment for cooling, degassing, vacuum distillation, moisture removal or freeze drying. They form a common part of ventilation systemswhere they serve as circulation air.sources They are used to ventilate rooms and workplaces, such as painting facilities or welding workshops. They are not affected by slightly volatile pollutants, and they can ventilate air from the galvanizing baths.
  • Industrial fans and blowers with side ducts create a vacuum that can be used for positive or negative pressure handling. Vacuum pressure can be distributed with the help of air nozzles, so that large areas can be gripped. In the printing industry they are used, for example, in paper handling systems and in the textile industry in weaving and knitting machines.
  • Many dust particles and gases are already highly explosive in their original state. ATEX-modified industrial fans are also deployed in more demanding environments. In chemical factories, biogas plants, mills, landfills, wastewater treatment plants or flour silos.
  • In agriculture , industrial fans supply pressure for the transport of granular and bulk materials in pressurized operations. They are used in feeding devices and dispensers for transporting feed, feathers, powders or tobacco. They form an integral part of dosing machines and composting plants.
  • Fans play a key role in aeration (introducing air into the less oxygenated material layers). They are used for aeration of water in breeding tanks, backwashing of filters and water oxygenation. In wastewater treatment plants , industrial fans are used in filtration units for aeration and blowing. 
  • Fans can be used in spa facilities, saunas and SPAs, where they are used as air sources for whirlpools.
  • Food processing technology uses airflow to blow out (discharge) a variety of media. Fans are applied here as air sources for drying in laundry facilities and dryers.
  • Fans have their place as a source of pressure and vacuum for the moving shipments in pipeline mail.
  • Air drying is one of the safest ways to preserve a product. Because of their design, the fans can work with heated air (up to 230 °C). Their use in air weldingor drying of synthetic granulate is therefore common.
VAKUUM BOHEMIA s.r.o.
Lidická kolonie 47
586 01 Jihlava
  Tel: +420 567 322 487
Fax: +420 567 330 560
Tel. services: +420 567 330 556
Urgent matters outside office hours: +420 602 806 203
  vakuum@ji.cz
www.Vakuum-Bohemia.cz

VAKUUM BOHEMIA, s.r.o. © 2016
vacuum pumps, blowers, compressors, vacuum, wholesale, retail, service, Busch, Becker, Leybold, Rietschle