Oil-free minicompressors
CONTACT
Lidická kolonie 47
586 01 Jihlava
Phone: +420 567 322 487
Service: +420 567 330 556
E-mail: info@vakuum-bohemia.cz
Oil-free minicompressors and mini vacuum pumps utilize a mobile piston for their operation. This equipment is intended to be included in other equipment, is oil-free, and does not require any lubrication. Models are sold in miniature one-stage and two-stage designs. Equipment can be used either as compressors or vacuum pumps. We have the most popular minicompressors in stock and it is also possible to borrow them for a test run.
Operating principles of minicompressors
This equipment relies on a mobile piston and is fitted with a four-pole motor, a capacitor starter, temperature fuse, and built-in cooling fan. The slow-running motor with 1400 rpm is silent and has a long service life. Motors are single phase, 220V, 50 Hz. Versions with 12 VDC, 24 VDC and 110V, 60 Hz are also available. The compressor suctions air, compresses it, and then expels it through the exhaust. Minicompressors are sealed with a Teflon O-ring and are completely oil-free.
Single-piston microcompressors up to 20 L |
Double-piston microcompressors up to 40 L |
||
RNS single-stage piston oil-free minicompressors are the smallest sources of compressed air or underpressure. Options: 230VAC, 110VAC, 24VDC, 12 VDC. Compressors are intended for inclusion in machines. |
RND double-stage piston oil-free minicompressors achieve greater pressure differences than single-stage compressors. Options: 230VAC, 110VAC, 24VDC, 12 VDC. Compressors are intended for inclusion in machines. |
||
Single-piston minicompressors up to 70 L |
Double-piston minicompressors up to 140 L |
||
The higher range of single-stage RNS minicompressors achieve higher flow than the smallest versions. Options: 230VAC, 110VAC, 24VDC, 12 VDC. Compressors are intended for inclusion in machines. |
The higher range of double-stage RND minicompressors achieve higher flow than the smallest versions. Options: 230VAC, 110VAC, 24VDC, 12 VDC. Compressors are intended for inclusion in machines. |
Parameters of minicompressors:
- pumping speed: from 10 litres/min up to 140 litres/min
- motor output: from 40W to 200W
- maximum overpressure between 2 bar and 10 bar
- maximum vacuum from 350 mbar (abs) up to 1 mbar (abs)
Advantages of minicompressors:
- maintenance-free
- reliable operation
- small size
- silent and vibration-free
Our services:
|
Applications:
|
Table of models
Model | Pumping speed [m3/h] | Max. negative pressure [mbar(g)] | Max. Overpressure [bar(g)] | Wattage [kW] | Note |
---|---|---|---|---|---|
10 RNS | 10 | 650 | 2 | 0,04 | To be built in |
15 RNS | 12 | 720 | 3 | 0,04 | To be built in |
18 RNS | 15 | 800 | 4 | 0,04 | To be built in |
20 RNS | 20 | 866 | 6 | 0,04 | To be built in |
10 RND | 2 x 10 | 650 | 2 | 0,06 | To be built in |
12 RND | 2 x 15 | 720 | 2,5 | 0,06 | To be built in |
15 RND | 2 x 18 | 800 | 4,5 | 0,06 | To be built in |
20 RND | 2 x 20 | 866 | 6 | 0,06 | To be built in |
40 RNS | 40 | 867 | 7 | 0,1 | To be built in |
50 RNS | 50 | 907 | 5 | 0,1 | To be built in |
60 RNS | 60 | 920 | 2 | 0,1 | To be built in |
70 RNS | 70 | 933 | N/A | 0,1 | To be built in |
40 RND | 40 | 960 | N/A | 0,2 | To be built in |
50 RND | 50 | 985 | N/A | 0,2 | To be built in |
60 RND | 60 | 993 | N/A | 0,2 | To be built in |
70 RND | 70 | 995 | N/A | 0,2 | To be built in |
80 RND | 80 | 866 | 7 | 0,2 | To be built in |
100 RND | 100 | 906 | 7 | 0,2 | To be built in |
120 RND | 120 | 920 | 4 | 0,2 | To be built in |
140 RND | 140 | 933 | 2 | 0,2 | To be built in |