Industrial (centrifugal) fans are used for moving gas or air. All models are designed for permanent operation. The supplied portfolio includes low-pressure, medium-pressure, and high-pressure industrial fans. Fans are produced in standard, special, stainless, or gas-tight versions. Versions with ATEX certification for explosive environments are also available.
Low-pressure fans
|
Medium-pressure fans
|
||
Low-pressure industrial fans represent a reliable source of overpressure or negative pressure for pressure differences of up to 2200 Pa. |
Medium-pressure industrial fans represent a reliable source of overpressure or negative pressure for pressure differences of up to 10 500 Pa. |
||
High-pressure fans
|
King-size fans
|
||
High-pressure industrial fans represent a reliable source of overpressure or negative pressure for pressure differences of up to 17 300 Pa. | King-size fans are standardised, custom-made low-pressure, medium-pressure, or high-pressure fans. |
Parameters of industrial fans:
- pumping speed: from 2 m3/h up to 6 600 m3/h
- motor power: from 0.03 kW to 500 kW
- max. underpressure: 0 – 30 000 Pa, based on motor output
- max. overpressure: 0 – 30 000 Pa, based on motor output
Main advantages of industrial fans:
- durable construction
- possibility of controlling the fan motor with a frequency converter
- long service life
- practically no maintenance required
Our services:
|
Applications:
|
List of models – LOW-PRESSURE fans
A low-pressure fan suitable for working with pressure differences of up to 2200 Pa. A fan with a directly connected motor. The stator is made of aluminium, and the impeller of zinc-covered sheet metal. Stainless versions and versions with ATEX certification for explosive environments are also available.
Model | Pumping speed [m3/min] | Max. negative pressure [Pa] | Max. Overpressure [Pa] | Wattage [kW] | Note |
---|---|---|---|---|---|
D 03 M or E 03 | 3,2 | 330 | 330 | 0,03 | |
D 04 M or E 04 | 5 | 350 | 350 | 0,07 | |
D 045 M or E 045 | 8 | 460 | 460 | 0,1 | |
D 05 M or E 05 | 10 | 430 | 430 | 0,13 | |
D 052 M or E 052 | 15 | 530 | 530 | 0,37 | |
D 060 or E 060 | 22 | 730 | 730 | 0,55 | |
D 064 or E064 | 27 | 1050 | 1050 | 1,1 | |
D 066 or E066 | 38 | 1200 | 1200 | 1,5 | |
D 07 | 41 | 1200 | 1200 | 2,2 | |
D 072 | 52 | 1200 | 1200 | 3 | |
D 08 | 50 | 1700 | 1700 | 2,2 | |
D 082 | 60 | 1700 | 1700 | 3 | |
D 09 | 80 | 1900 | 1900 | 5,5 | |
D 092 | 95 | 1900 | 1900 | 7,5 | |
2D 04 | 10 | 350 | 350 | 0,14 | |
2D 045 | 17 | 460 | 460 | 0,24 | |
2D 05 | 21 | 430 | 430 | 0,35 | |
2D 052 | 30 | 530 | 530 | 0,56 | |
2D 060 | 50 | 730 | 730 | 1,5 | |
2D 064 | 60 | 1000 | 1000 | 2,2 | |
2D 066 | 76 | 1200 | 1200 | 4 | |
2D 07 | 94 | 1200 | 1200 | 4 | |
2D 08 | 95 | 1900 | 1900 | 4 |
List of models – MEDIUM-PRESSURE fans
A medium-pressure fan suitable for working with pressure differences of up to 9600 Pa. The RD fan has direct propulsion and can have an integrated frequency converter (FUK). The stator and impellers are usually made of aluminium. Stainless versions and versions with ATEX certification for explosive environments are also available.
Model | Pumping speed [m3/min] | Max. negative pressure [Pa] | Max. Overpressure [Pa] | Wattage [kW] | Note |
---|---|---|---|---|---|
RD 0 or RE 0 | 2,7 | 650 | 650 | 0,04 | |
RD 10 or RE 10 | 4,9 | 1000 | 1000 | 0,075 | |
RD 14 | 11 | 1000 | 1000 | 0,25 | |
RD 15 or RE 16 | 16,5 | 1400 | 1400 | 0,37 | |
RD 2 or RE 2 | 11 | 2000 | 2000 | 0,37 | |
RD 4 or RE 4 | 13,5 | 2200 | 2200 | 0,55 | |
RD 5 or RE 5 | 18 | 2100 | 2100 | 0,55 | |
RD 6 or RE 6 | 21 | 2500 | 2500 | 0,75 | |
RD 62 | 27,5 | 3000 | 3000 | 1,1 | |
RD 64 | 35 | 3100 | 3100 | 1,5 | |
RD 65 | 40 | 2300 | 2300 | 2,2 | |
RD 7 | 50 | 3600 | 3600 | 2,2 | |
RD 72 | 43 | 3500 | 3500 | 3 | |
RD 74 | 61 | 3500 | 3500 | 4 | |
RD 8 | 55 | 5200 | 5200 | 5,5 | |
RD 82 | 88 | 5200 | 5200 | 7,5 | |
RD 84 | 90 | 6800 | 6800 | 11 | |
RD 92 | 125 | 8300 | 8300 | 15 | |
RD 94 | 125 | 9600 | 9600 | 22 |
List of models – HIGH-PRESSURE fans
A high-pressure fan suitable for working with pressure differences of up to 17 300 Pa. The fan either has a direct drive (FU) or a built-in frequency converter (FUK). Other versions have belt transmission and can be used with high revolutions – up to 6200 rpm. The stator and impellers are usually made of aluminium. Stainless versions and versions with ATEX certification for explosive environments are also available.
Model | Pumping speed [m3/min] | Max. negative pressure [Pa] | Max. Overpressure [Pa] | Wattage [kW] | Note |
---|---|---|---|---|---|
HRD 1T FU/FUK | 5,5 - 10,0 | 4900 | 4900 | 0,75 - 1,1 | |
HRD 14T FU/FUK | 10.24 | 4900 | 4900 | 1,1 - 2,2 | |
HRD 16T/FUK | 11,5 - 33,5 | 6100 | 6100 | 1,5 - 3 | |
HRD 2T FU/FUK | 7,7 - 27 | 8500 | 8500 | 1,5 - 3 | |
HRD 60 FU/FUK | 38 | 10150 | 10150 | 5,5 | |
HRD 65 FU/FUK | 32 | 8700 | 8700 | 7,5 | |
HRD 7 FU | 90 | 13000 | 13000 | 18,5 | |
HRD 1/2 T | 8 | 2800 | 2800 | 0,55 | |
HRD 1/3 T | 7,8 | 3300 | 3300 | 0,55 | |
HRD 1/4 T | 8 | 4200 | 4200 | 0,75 | |
HRD 1/5 T | 8,5 | 5100 | 5100 | 1,1 | |
HRD 14/5 T | 25 | 4500 | 4500 | 2,2 | |
HRD 2/3 T | 19,5 | 5600 | 5600 | 1,5 | |
HRD 2/4 T | 17 | 7700 | 7700 | 3 | |
HRD 2/5 T | 26 | 8600 | 8600 | 3 | |
HRD 60/4 | 20 | 10150 | 10150 | 4 | |
HRD 60/5 | 22 | 11400 | 11400 | 5,5 | |
HRD 60/7 | 47 | 11400 | 11400 | 7,5 | |
HRD 65/2 | 40 | 3900 | 3900 | 2,2 | |
HRD 65/4 | 52 | 5900 | 5900 | 4 | |
HRD 65/5 | 56 | 7500 | 7500 | 5,5 | |
HRD 65/7 | 62 | 8700 | 8700 | 7,5 | |
HRD 7/12 | 88 | 9000 | 9000 | 11 | |
HRD 7/17 | 90 | 13000 | 13000 | 18,5 | |
HRD 2/23 | 96 | 16400 | 16400 | 22 | |
HRD 1T | 10,5 | 4700 | 4700 | 1,1 | |
HRD 14T | 25 | 4500 | 4500 | 2,2 | |
HRD 2T | 27 | 8600 | 8600 | 3 | |
HRD 60 | 38 | 10150 | 10150 | 5,5 | |
HRD 65 | 62 | 8700 | 8700 | 7,5 | |
HRD 7 | 90 | 13000 | 13000 | 18,5 |
List of models – KING-SIZE fans
We also offer a range of very large industrial fans. These fans can be low, medium, or high-pressure. This type of fan is custom-made to suit the customer’s needs. The fan can have a direct, coupling, or belt connection. Fan revolutions can be controlled with a frequency converter. The impellers are made of steel or stainless steel. The size of fans in this line is always designed depending on the specific project. It is also possible to prepare versions for explosive environments (ATEX). Pumping speeds of up to 400 000 m3/h and max. pressure difference of 35 000 Pa.